Skip to content

Thermal insulation

Open-cell or closed-cell foam: compare actual products and assembly roles

By Review.LivePublished 3 min readHow we write

A fishing-lodge coordinator receives a request to replace the specified closed-cell roof foam with an open-cell product. The quotation lists a lower price but provides no comparison of thickness, vapour behaviour or the current roof detail.

A thick black ring binder packed with bound documents lies on a wooden desk.
Photo: Kelly Sikkema on Unsplash

Open-cell and closed-cell name foam structures, not complete roof designs. NRC’s example evaluations describe a light-density open-cell product and a medium-density rigid closed-cell product. Compare the actual proposed products and the assembly roles they are expected to perform. A familiar family name, sample colour or price does not establish equivalent performance at the specified thickness and location.

Build a located comparison before reviewing the swap

  1. Identify both actual products. Record the specified product, proposed replacement, current technical information and relevant evaluation references. Compare information on the same basis: thickness, units, test conditions and the distinction between an initial result and a design value. Mark a missing property as unanswered. Do not fill gaps with a generic internet value for every open-cell or closed-cell foam.
  2. Trace the required assembly roles. Read the roof or wall detail and identify the thermal requirement and separate air, vapour, moisture and fire-protection provisions. Ask which roles this product is intended to provide and how it connects to adjacent work. A component’s measured property does not show that every edge or penetration in the installed assembly performs that role.
  3. Compare the consequences by location. Record required installed depth, available space, product water and vapour information, permitted substrates and application conditions. Keep comparable material, installation and covering costs distinct from the quoted total. Put an uncertain moisture or vapour-control consequence to the responsible designer rather than assuming one foam family always suits a coastal or cold-climate roof.
  4. Refer the specific substitution question. Send the current detail, product evidence, affected locations and unanswered consequences through the project’s actual review process. Obtain the received decision and any changed installation or verification requirements before revising the crew sheet. A procurement preference is useful information, but it does not independently replace the approved assembly or authorize a different foam.

Common mistakes

  • Comparing family names instead of actual products.
  • Mixing initial thermal results with design values.
  • Assuming a foam sample proves an installed air-control layer.
  • Changing the specified material before receiving the assembly answer.

Checklist

The foam comparison should retain

  • Specified and proposed product identification.
  • Comparable property values, units and thickness basis.
  • Located thermal and separate control-layer roles.
  • Space, application, covering and cost consequences.
  • Received substitution decision and changed checks.

Check your understanding

Both products have a thermal-resistance number. Is that enough to approve the roof substitution?

Show the answer
Compare the actual design basis and thickness, then trace the other assembly roles and installation conditions. Refer unanswered moisture, vapour and protection consequences through the required review. One thermal number does not establish complete equivalence for this roof.

Sources

  1. CCMC 14444-R — light-density open-cell product informationNational Research Council Canada, Canadian Construction Materials Centre · Specific evaluated product and stated code editions; not a general approval for all open-cell foams or roof assemblies · accessed
  2. CCMC 14230-R — closed-cell product, substrate and high-lift limitationsNational Research Council Canada, Canadian Construction Materials Centre · Specific Canadian evaluation; its formulation and application limits are not universal spray-foam instructions · accessed