Why structural steel needs fireproofing and what an hourly rating means

By Review.LivePublished 3 min readHow we write

During a parkade walk, a ductwork foreman points at the sprayed beams and asks why steel needs protection. Some steel on the floor above looks bare. You need a clear explanation and the right drawing, rather than a guess about what the designer intended.

Steel canopy framing and stacked materials stand beside an unfinished block building.
Photo: Michael Quinn / National Park Service on Wikimedia Commons · Grand Canyon, Bright Angel Trailhead Construction Overview 0408 - Flickr - Grand Canyon NPS · CC BY 2.0 · Cropped, resized, colour adjusted and sharpened. No claim to original U.S. Government works.

Structural steel loses strength as its temperature rises; fireproofing provides protection against heating. An hourly fire-resistance rating describes performance under specified test conditions. It does not promise that a particular building will remain safe for that many hours in every real fire, or establish that it can be reused afterwards.

Explain the purpose against the actual scope

  1. Start with the load being carried. Point to the beam, column or supporting assembly on the drawing. Explain that the concern is maintaining its intended structural function during the specified fire exposure. Keep the discussion about protection of the structure rather than whether the steel itself looks combustible.
  2. Locate the rating requirement. Open the current fire-resistance schedule and relevant design information with the superintendent or consultant. Identify the location and element being discussed. Do not assign a rating from the number of storeys, the appearance of the spray or a neighbouring project's requirements.
  3. Describe the hour correctly. Use the project's actual rating as the example and explain that it belongs to a specified tested construction. Keep emergency decisions with the project's emergency arrangements and responsible authorities. Never tell a crew that a rated assembly gives them a guaranteed working or escape period.
  4. Check the apparently bare area. Mark its grid and level and ask the consultant how protection is provided or whether the documents contain an omission. A ceiling, enclosure or another design arrangement needs confirmation from the actual documents. The absence of visible spray is a question to resolve, not evidence that protection is unnecessary.
  5. Translate the answer into trade behaviour. Tell the ductwork foreman which locations are protected, where the current documents can be found and who to contact before an attachment changes them. Record observed damage and arrange the project's repair review. Do not allow the explanation to become permission to scrape material away.
  6. Keep the unresolved point visible. Record the consultant's answer or the outstanding query alongside the location reference. Brief affected trades again when the answer changes the work. Keep any outstanding design question visible.

Common mistakes

  • Answering a scope question from the colour of the steel.
  • Using the rating as a countdown for people to keep working.
  • Treating damage as cosmetic because the underlying steel is intact.

Checklist

Carry a short scope explanation

  • Member and location being discussed.
  • Current rating and design reference.
  • Plain explanation of heat protection.
  • Bare or damaged locations needing review.
  • Trade contact before altering protection.

Check your understanding

A beam upstairs has no visible spray. Can you tell the crew that it needs no fire protection?

Show the answer
Check the actual rated scope and protection detail with the consultant. Visible appearance does not establish the design requirement, and an unresolved location should remain a recorded query.

Sources

  1. Standard Test Methods for Fire-Resistive Steel — high-temperature strength principleNational Institute of Standards and Technology · United States; material research principle, not project design criteria · accessed
  2. CAN/ULC-S101 — public scope and limitationsUL Standards & Engagement · Canada; public standard scope only, not the full paid standard · accessed